DCA400 SERIES — FUEL RETURN LINE KIT INSTRUCTIONS P/N 35499 — REV. #0 (01/26/11) — PAGE 4
INSTALL NEW RETURN EXTENSION HOSE
Refer to Figure 9.
1. Connect Item 6, return extension hose, to item 4.
Secure with clamp, Item 5.
2. Install Item 7, straight fitting, between extension hose
and existing engine return hose. Secure with clamps.
Figure 9. New Return Extension Hose
3. Install spiral tubing, Item 10, around return extension
hose. Secure with cable ties, Item 9. See Figure 10.
5
5
5
7
6
Engine
Return Hose
4
Figure 10. Spiral Tubing
INSTALL NEW VENT HOSE
1. Connect Item 8, vent hose, to generator pick-up port and
return port. Secure with clamps, Item 5. See Figure 11.
Figure 11. Vent Hose
9
9
10
5
5
8
Pick-Up
Port
Return
Port