DCA400 SERIES — FUEL RETURN LINE KIT INSTRUCTIONS P/N 35499 — REV. #0 (01/26/11) — PAGE 2
DISASSEMBLY
Figure 2 illustrates the unit’s current fuel line configuration.
Figure 2. Current Fuel Line Configuration
1. Turn fuel shut-off valve to the OFF position (Figure 3).
Figure 3. Fuel Shut-Off Valve (Off Position)
Generator
Fuel Tank
Drain
Trailer
Fuel Tank
Engine
Return
Hose
Pick-Up
Hose
NOTICE
Fuel leaks may occur when disconnecting hoses and
fittings. Wipe up any spilled fuel immediately.
Trailer
Fuel Tank
Drain
Fuel Shut-Off
Valve (OFF Position)
2. Disconnect pick-up hose from pick-up port and discard.
See Figure 4.
Figure 4. Remove/Discard Pick-Up Hose
3. Disconnect engine return hose from return port. See
Figure 5.
Figure 5. Disconnect Engine Return Hose
Remove/Discard
Pick-Up Hose
Pick-Up
Port
Disconnect
Engine Return
Hose
Return
Port